HomeMy WebLinkAboutHirschdale 2018 CCR Final PublicationTruckee Donner Public Utility District
2018 WATER QUALITY REPORT
In This Document
Water Quality General Information
Source Water Assessment
Where Our Water Comes From
Lead In Drinking Water
Definitions
Sampling Results
Este informe contiene información muy importante sobre su agua potable. Tradúzcalo o hable
con alguien que lo entienda bien.
Customer Views Are Welcome
I f you are interested in participating in the decision -making process of
the Truckee Donner Public Utility District, you are welcome to attend
Board Meetings.
The Board of Directors meets at 6:00 PM on the first and third Wednesday
of each month in the TDPUD Board room, located at 11570 Donner Pass
Road, Truckee, California. Agendas for upcoming meetings may be
obtained on our website or from the Deputy District Clerk ’s office,
(530)582-3980.
For More Information:
About this report or the water treatment process, contact Truckee
Donner Public Utility District’s Senior Water Quality Technician, Clay
Walker at (530)582-3926.
About water conservation and efficiency, the TDPUD has water
conservation programs that will help customers save water and save
money. Information can be found on our website or by calling (530)
587-3896.
Hirschdale Water System PWS# 2910010
For more
information about
us, please visit our
website at
www.tdpud.org .
Water Quality
T ruckee Donner Public Utility District is able to report that it has met all State
and Federal drinking water standards. The data in this brochure is a
snapshot of the quality of water provided to TDPUD customers for the 2018
calendar year. Included in this document are details about where your water
comes from, what it contains, and how it compares to State and USEPA
standards.
Truckee Donner Public Utility District is committed to providing you with the
information about your water supply because customers who are well informed
are the District’s best allies in supporting improvements that are necessary to
maintain the highest drinking water standards.
Some people may be more vulnerable to contaminants in drinking water than the
general population. Immuno-compromised persons such as persons with cancer
undergoing chemotherapy, people who have undergone organ transplants, people
with HIV/AIDS or other immune system disorders, some elderly individuals, and
infants can be particularly at risk from infections. These people should seek advice
about drinking water from their health care providers. USEPA/Centers for Disease
Control (CDC) guidelines on appropriate means to lessen the risk of infection by
Cryptosporidium and other microbiological contaminants are available from the
Safe Drinking Water Hotline at (800)426-4791 or https://www.epa.gov/ground-
water-and-drinking-water/safe-drinking-water-hotline.
Lead in Home Plumbing
I f present, elevated levels of lead can cause serious health problems, especially
for pregnant women and young children. Lead in drinking water is primarily
derived from materials and components associated with service lines and home
plumbing. TDPUD is responsible for providing high quality water, but cannot
control the variety of materials used in plumbing components. When your water
has been sitting for several hours, you can minimize the potential for lead
exposure by flushing your tap for 30 seconds to 2 minutes before using water for
drinking or cooking.
We conduct routine sampling for lead every three years. The last sampling was
performed in 2016, where all sites tested below the Federal action level for lead.
More information about lead in drinking water, testing methods, and steps you can
take to minimize exposure can be found at www.epa.gov /lead.
Where Our Water Comes From
T he source of drinking water served to our Hirschdale customers comes from
a well drawing from a deep aquifer. We filter this water to remove iron,
manganese, and arsenic before delivering it to your home.
Additionally, each month the system is sampled for microbial quality. Because of
natural filtration, the groundwater aquifer is protected from surface water
contamination, giving us a high quality of drinking water.
Cryptosporidium and Giardia
S ince we source from a deep well, it is almost impossible to have microscopic
organisms such as Cryptosporidium and Giardia in our water. If ingested,
Cryptosporidium and Giardia can cause diarrhea, fever, and other gastrointestinal
symptoms.
Source Water
Assessment
A source water assessment has
been completed for the well
serving the Hirschdale area. The well
is considered most vulnerable to the
following activities not associated
with any detected contaminants:
septic systems, drinking water
treatment plants, and transportation
corridors. A copy of the complete
assessment may be viewed at the
Truckee Donner Public Utility District
office, located at 11570 Donner Pass
Road, Truckee, California, or by
calling Brian Wright at
(530)582-3957.
Substances That Could Be In Water
T he sources of drinking water (both tap
and bottled water) include rivers, lakes,
streams, ponds, reservoirs, springs, and
wells. As water travels over the surface of the
land or through the ground, it dissolves
naturally-occurring minerals and, in some
cases, radioactive material, and can pick up
substances resulting from the presence of
animals or from human activity.
In order to ensure that tap water is safe to
drink, the U.S. Environmental Protection
Agency (USEPA) and the State Water
Resources Control Board (State Board)
prescribe regulations that limit the amount of certain contaminants in water
provided by public water systems. State Board regulations also establish limits
for contaminants in bottled water that provide the same protection for public
health. Drinking water, including bottled water, may reasonably be expected to
contain at least small amounts of some contaminants. The presence of
contaminants does not necessarily indicate that water poses a health risk.
Contaminants that may be present in source water include :
Microbial Contaminants, such as viruses and bacteria, that may come
from sewage treatment plants, septic systems, agricultural livestock operations,
and wildlife;
Inorganic Contaminants, such as salts and metals, that can be
naturally occurring or can result from urban stormwater runoff, industrial or
domestic wastewater discharges, oil and gas production, mining, or farming;
Pesticides and Herbicides, that may come from a variety of sources such
as agriculture, urban stormwater runoff, and residential uses;
Organic Chemical Contaminants, including synthetic and volatile organic
chemicals, which are by-products of industrial processes and petroleum
production, and which can also come from gas stations, urban stormwater
runoff, agricultural applications, and septic systems;
Radioactive Contaminants, that can be naturally occurring or can be the
result of oil and gas production and mining activities.
More information about contaminants and potential health effects can be
obtained by calling the U.S. EPA’s Safe Drinking Water Hotline at (800) 426-
4791.
Definitions
Maximum Contaminant Level (MCL): The highest
level of a contaminant that is allowed in drinking water.
Primary MCLs are set as close to the PHGs (or MCLGs)
as is economically and technologically feasible.
Secondary MCLs are set to protect the odor, taste, and
appearance of drinking water.
Maximum Contaminant Level Goal (MCLG): The level
of a contaminant in drinking water below which there is
no known or expected risk to health. MCLGs are set by
the U.S. Environmental Protection Agency (USEPA).
Public Health Goal (PHG): The level of a contaminant
in drinking water below which there is no known or
expected risk to health. PHGs are set by the California
Environmental Protection Agency.
Maximum Residual Disinfectant Level (MRDL): The
highest level of a disinfectant allowed in drinking water.
There is convincing evidence that addition of a
disinfectant is necessary for control of microbial
contaminants.
Maximum Residual Disinfectant Level Goal (MRDLG):
The level of a drinking water disinfectant below which
there is no known or expected risk to health. MRDLGs do
not reflect the benefits of the use of disinfectants to
control microbial contaminants.
Primary Drinking Water Standards (PDWS): MCLs
and MRDLs for contaminants that affect health along with
their monitoring and reporting requirements, and water
treatment requirements.
Secondary Drinking Water Standards (SDWS): MCLs
for contaminants that affect taste, odor, or appearance of
the drinking water. Contaminants with SDWSs do not
affect the health at the MCL levels.
Regulatory Action Level (AL): The concentration of a
contaminant which, if exceeded, triggers treatment or
other requirements that a water system must follow.
Table Key
N/A: not applicable
N/D: not detectable at testing limit
ppm: parts per million or milligrams per liter (mg/L)
ppb: parts per billion or micrograms per liter (µg/L)
ppt: parts per trillion or nanograms per liter (ng/L)
pCi/L: picocuries per liter (a measure of radiation)
(μS/cm): micro Siemens per centimeter
(NTU): nephelometric turbidity unit (measures water cloudiness)
The data in the following tables is from the most recent monitoring done in compliance with Federal and Califor-
nia drinking water regulations. Some data may be more than one year old. Based upon Federal and State re-
quirements, the monitoring interval for each constituent varies, and can be any one of the following: weekly,
monthly, semi-annually, annually, biennially, or once every three, six, or nine years, or as deemed necessary by
regulatory agencies.
TABLE 1 – SAMPLING RESULTS SHOWING THE DETECTION OF COLIFORM BACTERIA
Microbiological Con-
taminants
Highest
No. of
Detections
No. of months in
violation MCL MCLG Typical Source of Bacteria
Total Coliform Bacteria 0 0
More than 5% of sam-
ples in a month with a
detection
0 Naturally present in the environ-
ment
TABLE 2 – DISINFECTION BY-PRODUCTS
Contaminant
# Sam-
ples, Fre-
quency
Average
Level Range MCL (MRDL) MCLG
(MRDLG)
Typical Source of Contami-
nant
Chlorine Residual (ppm) 1 per month 0..48 0.42-0.52 4 4 Drinking water disinfectant added
for treatment
Total Trihalomethanes
(ppb)
1 on
9/11/18 21 N/A 80 N/A By-product of drinking water
disinfection
Haloacectic Acids (ppb) 1 on
9/11/18 9.0 N/A 60 N/A By-product of drinking water
disinfection
TABLE 3 – DISTRIBUTION SYSTEM CUSTOMER TAP SAMPLING FOR LEAD AND COPPER
Lead and Copper Date Last
Sampled
No. of
samples
collected
90th
percen-
tile level
detected
No. sites
exceeding
AL
AL PHG Typical Source of Contami-
nant
Lead (ppb) 08/10/16 5 1.5 0 15 0.2
Internal corrosion of household
water plumbing systems; discharg-
es from industrial manufacturers;
erosion of natural deposits
Copper (ppm) 08/10/16 5 0.074 0 1.3 0.3
Internal corrosion of household
plumbing systems; erosion of
natural deposits; leaching from
wood preservatives
TABLE 4 – SAMPLING RESULTS FOR SODIUM AND HARDNESS
Chemical or Constituent
(reporting units)
Date Last
Sampled
Level De-
tected
Range of Detec-
tions MCL PHG
(MCLG)
Typical Source of Contami-
nant
Sodium (ppm) 2016 43 N/A N/A N/A Salt present in the water and is
generally naturally occurring
Hardness (as CaCO3)
(ppm) 2016 91 N/A N/A N/A
Sum of polyvalent cations pre-
sent
in the water, generally magnesi-
um and calcium, and are usually
naturally occurring
TABLE 5- UNREGULATED COMPOUNDS
Chemical or Constituent
(reporting units)
Date Last
Sampled
Level Detect-
ed
Range of De-
tections MCL PHG
(MCLG)
Typical Source of Contami-
nant
Alkalinity (as CaCO3)
(ppm) 2016 150 N/A N/A N/A Erosion of natural deposits
Bicarbonate Alkalinity
(as HCO3) (ppm) 2016 180 N/A N/A N/A Leaching of natural deposits
Calcium (ppm) 2016 15 N/A N/A N/A Erosion of natural deposits
Magnesium (ppm) 2016 13 N/A N/A N/A Erosion of natural deposits
Potassium (ppm) 2016 7.4 N/A N/A N/A Erosion of natural deposits
TABLE 6 – DETECTION OF CONTAMINANTS WITH A PRIMARY DRINKING WATER STANDARD
Chemical or Constitu-
ent
(reporting units)
Date Last
Sampled
Level Detect-
ed
Range of De-
tections MCL PHG
(MCLG)
Typical Source of Contami-
nant
Inorganic Contaminants
Arsenic (ppb) 2016 4.2 N/D-6.6 10 0.004 Erosion of natural deposits
Barium (ppm) 2016 74 N/A 1000 2000 Erosion of natural deposits
Fluoride (ppm) 2016 0.09 N/A 2 1 Erosion of natural deposits
Turbidity (NTU) 2016 2.30 N/A 5 5 Soil runoff
Radioactive Contaminants
Gross Alpha Particle
Activity (pCi/L) 2018 N/D 3 15 0 Erosion of natural deposits
Radon (pCi/L) 2005 570 N/A N/A* N/A* Erosion of natural deposits
*Note The State of California does not have an MCL for Radon. The EPA has an advisory MCL of
4000 pCi/L
for Radon.
TABLE 7 – DETECTION OF CONTAMINANTS WITH A SECONDARY DRINKING WATER STANDARD
Chemical or Constitu-
ent
(reporting units)
Date Last
Sampled
Level Detect-
ed
Range of De-
tections MCL PHG
(MCLG)
Typical Source of Contami-
nant
Chloride (ppm) 2016 6 N/A 250 N/A Leaching of natural deposits
Iron (ppb) 2016 90 N/A 300 N/A Leaching of natural deposits
Manganese (ppb) 2016 5.90 N/A 50 N/A Leaching of natural deposits
pH 2016 8.0 7.7 - 8.3 6.5 - 8.5 N/A Erosion of natural deposits
Specific Conductance
(μS/cm) 2016 350 N/A 1600 N/A
Substances that form ions when
in
water.
Sulfate 2016 14 N/A 250 N/A Leaching of natural deposits
Total Dissolved Solids
(ppm) 2016 260 N/A 500 N/A Leaching of natural deposits