HomeMy WebLinkAbout11 Substation TestingTRUCKEE DONNER Public Utility District MEETING DATE: October 7, 2020 TO: Board of Directors AGENDA ITEM #11 FROM: Sanna Schlosser, P.E., Electric Engineering Manager SUBJECT: Award of Contract for Substation Testing Services APPROVED BY Joe Horvath, Assistant General Manager/Electric Utility Director RECOMMENDATION: Authorize the General Manager to execute the Confirmation under the NCPA Support Services Agreement (Attachment 1), and all necessary documents, with Northern California Power Agency for the procurement of substation testing services from NorCal Power Services in the amount of $71,645, plus a 10% change order authorization, and associated NCPA fees of $685, for an amount not to exceed $79,494. DISCUSSION: Consistent with industry standards, formal in-depth testing of substation equipment should be performed every 5 years. This testing is a critical component in maintaining a safe, efficient, and reliable electric distribution system. While staff performs monthly visual inspections at all substations, Martis Valley Substation has not undergone in-depth testing within this interval and is due for testing. In addition, staff is developing a testing plan and schedule for remaining substations in future years. Staff contacted NorCal Power Services (NorCal) for a quote to perform substation testing services. NorCal provided a quote of $71,645 to perform this work (Attachment 1). Staff has reviewed the quote and determined that it is comprehensive and fulfills District requirements. In September 2020, Northern California Power Agency (NCPA) awarded a multi -year contract with NorCal for substation testing and other services as part of NCPA's Support Services Program Agreement (SSPA). Section 3.08.060 of District Code (Joint Purchasing with the State of California and other public agencies) permits the District to take advantage of other agencies' competitive bid procurement processes. As a NCPA member, the District can utilize the SSPA for support services. The SSPA was approved Page 1 of 2 by the Board on November 2, 2016. Through the SSPA, NCPA will administer the contract with NorCal on behalf of the District and NorCal will perform the work. Documentation for the proposed services from NorCal using the SSPA process is included as Attachment 1. This item is in support of the following objectives and goals identified by the District: 1.05.020 Objectives: 4. Provide reliable and high quality electric supply and distribution system to meet current and future needs. 6. Manage the District is an effective, efficient and fiscally responsible manner. 1.05.030 Goals: 4.5. Provide effective and efficient maintenance and replacement programs. 6.1. Utilize modern, cost effective work methods and equipment. FISCAL IMPACT: The Board approved Electric Department Operating Budget for FY20 included $216,845 for Substation Operations. As of 9/23/20, the District has spent about $154,000 of this budgeted amount, leaving $62,845 in the account. Sufficient funds remain in the FY20 Budget for the procurement of these proposed services. ATTACHMENTS: Attachment 1: Confirmation under the NCPA Support Services Agreement Town Council Staff Report Page 2 of 2 CONFIRMATION UNDER THE NCPA SUPPORT SERVICES PROGRAM AGREEMENT 1. This is a Confirmation pursuant to the Support Services Program Agreement and subject to the terms and conditions of that agreement, except as expressly provided in this Confirmation. All capitalized terms have the meaning given to them in the Support Services Program Agreement. 2. The Participating Member for this Confirmation is the TRUCKEE DONNER PUBLIC UTILITY DISTRICT in the amount of not -to -exceed $78,809.00 for the NorCal Power Services LLC services described in paragraph 3. This amount includes $71,645.00 for the proposed services, plus a 10% contingency in the amount of $7,164.00. This is not a guarantee that the full amount will be paid to NorCal Power Services, but is merely a limit of potential expenditures for services under this Confirmation. 3. TRUCKEE DONNAR PUBLIC UTILITY DISTRICT requests the following described Support Services in the dollar amount specified above, as follows: NorCal Power Services LLC shall perform maintenance testing at the Martis Valley Substation as detailed in its proposal dated September 30, 2020, copy attached. 4. The Participating Member executing this Confirmation agrees to pay for the Support Services in the not to exceed amount specified in paragraph 2, above; plus, the Administrative Cost of $685.00 to develop the Confirmation and first month of administration in accordance with the provisions of the Support Services Program Agreement. The total amount expended under this Confirmation will not exceed �79,494.00. 5. A Security Account deposit is not required for this Confirmation. Date: Participating Member: TRUCKEE DONNER PUBLIC UTILITY DISTRICT By its Designated Representatives: General Manager And (See March 3, 2017 Blanket Authorization General Counsel And Board President Date: NORTHERN CALIFORNIA POWER AGENCY Randy S. Howard, General Manager Assistant Secretary to NCPA Commission Approved as to form: Jane E. Luckhardt, NCPA General Counsel ES-AGY-2016-001 Confirmation No. 0194 Truckee Donner Public Utility District March 3, 2017 Northern California Power Agency 651 Commerce Drive Roseville, CA 95678 Attn: Randy S. Howard SUBJECT: Support Services Program Agreement Approval by General Counsel as Designated Representative Directors JosOph R. Aguera Jeff Bender Bob Ellis Tony Lallotis Paul Warmerdam General Manager Michael D. Holley The Board of Directors of the Truckee Donner Public Utility District ("TDPUD") approved execution of the Support Services Program Agreement (" SSPA' with the Northern California Power Agency ("NCPA') as of November 2, 2016. Pursuant to the SSPA terms, TDPUD is now a Signatory Member. The SSPA requires, for any Support Services provided thereunder, the execution of a written Confirmation by "Designated Representatives" of the Signatory Member. The SSPA defines "Designated Representatives" as "both its Utility Director (or an employee or official other than the Utility Director designated by resolution of the Signatory Member's Governing Board) and its City Attorney or General Counsel, acting jointly." As General Counsel for TDPUD, I hereby agree that this document constitutes my joint approval as a Designated Representative for all individual Confirmations executed by TDPUD's General Manager in an amount not more than $15,000 and all individual Confirmations executed by TDPUD's General Manager and Board President, upon approval by TDPUD's Board of Directors, in an amount over $15,000 but not more than $250,000, which approval shall remain valid and in effect until revoked by written Notice to NCPA. 5�;� Steven C. Gross TDPUD General Counsel 11570 Donner bass Rd, Truckee, CA 96161 - Phone 530-887.38%- www, gM4,or ©ma© NorCa/ Power Services Loomis, CA 95650 (775 )741-4012 Aaron.Sto a norcal o rs-rvices.com Shipping: N/A Terms: Net 30 Quotation Quote No: Q202027 Date: 9/30/2020 TRUCKEE DONNER P.U.D. - MARTIS VALLEY SUBSTATION MAINTENANCE TESTING Customer: Sanna Schlosser Truckee Donner P.U.D. 11570 Donner Pass Rd. Truckee, CA 96161 (530) 582-3945 sannaschlosser td ud.or Ship to: Truckee Donner P.U.D. Martis Valley Substation 10958 River View Dr. Truckee, CA 96161 Net Extended Line City UOM Description Tax Price Pricy+ 1 1 JOB Perform maintenance testing on substation equipment per SOW below 56,100.00 56,100.00 2 1 JOB Mobilization, lodging, meals 5,145.00 5,145.00 3 1 JOB Substation battery maintenance and load testing per SOW below 4,800.00 4,800.00 4 1 WEEK 60' 4x4 articulating boom rental 4,200.00 4,200.00 5 1 EACH Supply Qualitrol liquid temp gauge 5" Alarm Thermometer (2 switch) Model # 167-224-03 1,400.00 1,400.00 X Approver (print) Subtotal: $ 71,645.00 Tax: 0.00 X Total: $ 71,645.00 Approver (sign) Date SOW: Qty(1) S&C SF6 Circuit Switcher XA25 Wipe down all bushings and insulators Contact resistance Check mechanical operation manually Check mechanical operation electrically Qty(4) General Electric 5000kVA Oil Filled Transformer Wipe down all bushings Visual inspection SFRA (this would be a baseline test to compare to if SFRA performed after a major fault) Turns ratio Winding resistance Winding power factor Bushing power factor C1 test Exciting current Leakage reactance (measures transformer impedance and compare to nameplate) Insulation resistance Core ground resistance if core ground bushing is accessible Test rapid pressure rise relay if equipped Test oil & winding temp devices if equipped (liquid temp confirmed) Page 1 of 3 CT's on H1 bushing. Per drawing Outdoor Wiring Diagram, only the C5 CT's are being used for relaying. Single point ground Ratio Winding resistance Excitation Qty(3) 120kV Surge Arresters Wipe down arresters Insulation resistance Watts loss Qty(3) Cooper Power Systems 667kVA Voltage Regulators VR-1, VR-2, VR-3 Wipe down all bushings Visual inspection Insulation resistance Turns ratio on all taps Dynamic winding resistance on all taps Contact resistance on isolation and bypass knife switches Qty(6) CT's located above voltage regulators Visual inspection Single point ground test Ratio test Qty(2) PT's located above voltage regulators Visual inspection Ratio test Qty(3) CT's located down stream of VR's and used for differential protection Visual inspection Single point ground test Ratio test Winding resistance Excitation Qty(3) PT's located down stream of VR's. Bph used for 81U Visual inspection Ratio test Qty(12) 12kV Switches - MVS-001, 01, 02, 03, 04 & MVL-11, 12, 21, 31, 41, 23, 34 Visual inspection Clean Contact resistance Qty(4) Kyle RecloserType Nova 15 Visual inspection Clean bushings Contact resistance High potental test Qty(12) Single phase 12kV knife switches Visual inspection Contact resistance Qty(1) SEL-551 overcurrent protection relay Record as -found settings Test relay protection settings and logic/trip outputs SEL-587 transformer differential Page 2 of 3 Record as -found settings Test relay protection settings and logic/trip outputs Qty(1) Basler BE1-81 under frequency relay Record as -found settings Test relay protection settings and trip output Qty(1) 125VDC battery bank Specific gravity test Internal impedence Disconnect, clean and re -connect poor connections Load test battery bank per manufacturer specification - This quote does not include any extra parts or material for any apparatus above what is included in this quote. If any additional parts or material are deemed necessary, a separate quote can be provided. - NCPS will not perform any energized switching. If energized switching is requested, a price can be provided. - NCPS will provide (as needed) ground bridals, generators, test equipment, cleaning equipment, LOTO locks, PPE. Page 3 of 3