Loading...
HomeMy WebLinkAboutRes 8114i( I RESOLUTION NO. 8114 OF THE TRUCKEE DONNER PUBLIC UTILITY DISTRICT APPROVING SPECIFICATIONS AND ISSUING A CALL FOR BIDS ON EMERGENCY GENERATOR/ALTERNATOR I WHEREAS, the Board of Directors of the Truckee Donner Public Utility District has determined the need to purchase an electric generator for emergency use; and WHEREAS, three different specification sheets with various size generators have been attached hereto and marked Exhibits A, B and C; NOW, THEREFORE, BE IT RESOLVED by the Board of Directors of the Truckee Donner Public Utility District as follows: 1. That the specifications described in Exhibits A, B and C attached hereto and made a part hereof are approved. 2. That the President of the Board is hereby directed to issue a call for bids based on the specifications at- tached hereto for one (1) generator for emergency use. 3. That the date and time established for the bid opening is March 6, 1981, at 4:30 P.M. PASSED AND ADOPTED by the Board of Directors of the Truckee Donner Public Utility District at a regular meeting thereof duly called and held in the District on the 2nd day of February, 1981, by the following roll call vote: AYES: Duffy, Kuttel, Maass and Huber. NOES: None. ABSENT: Sutton. TRUCKEE DONNER PUBLIC UTILITY DISTRICT Jthr&P.iL.L. Roberta C. Huber, President I ATTEST i-_* 70L ci* ■J±- S\»«an M. Craig, Deputy District clerk TRUCKEE-DONNER PUBLIC UTILITY DISTRICT POST OFFICE BOX S09 TRUCKEE, CALIFORNIA 9S734 TELEPHONE 587-3B96 I The Truckee-Donner Public Utility District is requesting quotations on the following Generators/Alternators. The specifications and descriptions are taken from the Onan catalogue. Any and all differences of these specifications and descriptions must be listed and marked. It is not the District's intent to exclude any responsible manu- facturer or dealer with the use of these specifications. The Truckee-Donner P.U.D. specifically reserves the right to reject any and all bids, waive irregularities or informalities in any or all bids, be the sole judge of the suitability of the items offered, and to accept any bids it determines to be in its best interest. SPECIFICATIONS FOR GENERATORS I Manufacturer 7.5 KW Single Phase 60 Hertz Voltage 120/240 Amps 63 Wire 4 Kva 15.0 3 1.0 P.F. Model I Standard Equipment: Vibration Isolators Muffler Flexible Exhaust Connection Air Cleaner with Reusable Polyurethane (oil wetted) Element Carburetor Air Preheater (gasoline models only) Spin-on Full Flow Lube Oil Filter Oil Pressure Gauge Removable Lifting Bracket Mounted Control Box with fused DC Controls, Charge Rate Ammeter, Start-Stop Switch, Exciter Circuit Breaker, Manual Reset, Remote Control Terminals Mounted Connection Box Battery Cables Optional Equipment: Gas/Gaso Carburation Weather Protective Housing Mounted Exhaust Mounted Fuel Tank Low Oil Pressure Shutdown Hot Air Temperature Shutdown Installed Oil Base Heater Batteries and Electrolyte S TRUCKEE-DONNER PUBLIC UTILITY DISTRICT POST OFFICE BOX 309 TRUCKEE, CALIFORNIA 95734 TELEPHONE 587-3896 I The Truckee-Donner Public Utility District is requesting quotations on the following Generators/Alternators. The specifications and descriptions are taken from the Onan catalogue. Any and all differences of these specifications and descriptions must be listed and marked. It is not the District's intent to exclude any responsible manu- facturer or dealer with the use of these specifications. The Truckee-Donner P.U.D. specifically reserves the right to reject any and all bids, waive irregularities or informalities in any or all bids, be the sole judge of the suitability of the items offered, and to accept any bids it determines to be in its best interest. SPECIFICATIONS FOR GENERATORS I Manufacturer 10 KW Single Phase 60 Hertz Voltage 120/240 Amps 63 Wire 4 Kva 15.0 i 1.0 P.F. Model it Standard Equipment: Vibration Isolators Muffler Flexible Exhaust Connection Air Cleaner with Reusable Polyurethane (oil wetted) Element Carburetor Air Preheater (gasoline models only) Spin-on Full Flow Lube Oil Filter Oil Pressure Gauge Removable Lifting Bracket Mounted Control Box with fused DC Controls, Charge Rate Ammeter, Start-Stop Switch, Exciter Circuit Breaker, Manual Reset, Remote Control Terminals Mounted Connection Box Battery Cables Optional Equipment: Gas/Gaso Carburation Weather Protective Housing Mounted Exhaust Mounted Fuel Tank Low Oil Pressure Shutdown Hot Air Temperature Shutdown Installed Oil Base Heater Batteries and Electrolyte n TRUCKEE-DONNER PUBLIC UTILITY DISTRICT POST OFFICE BOX 309 TRUCKEE, CALIFORNIA 95734 TELEPHONE 587-3896 I The Truckee-Donnor Public Utility District is requesting quotations on the following Generators/Alternators. The specifications and descriptions are taken from the Onan catalogue. Any and all differences of these specifications and descriptions must be listed and marked. It is not the District's intent to exclude any responsible manu- facturer or dealer with the use of these specifications. The Truckee-Donner P.U.D. specifically reserves the right to reject any and all bids, waive irregularities or informalities in any or all bids, be the sole judge of the suitability of the items offered, and to accept any bids it determines to be in its best interest. SPECIFICATIONS FOR GENERATORS I Manufacturer 15 KW Single Phase 60 Hertz Voltage 120/240 Amps 03 Wire 4 Kvu 15.0 | l.Q P.P. Node! I standard Equipraenti Vibration Isolators Muffler Flexible Exhaust Connection Air Cleaner with Reusable Polyurethane (oil wetted) Element Carburetor Air Preheater (gasoline models only) Spill-On Full Flow Lube Oil Filter Oil Pressure Gauge Removable Lifting Bracket Moun1 cd Control Box with fused DC Controls, Charge Rate Amineter, Start-Stop Switch, Exciter Circuit Breaker, Manual Reset, Remote Control Terminals Mounted Connection Box Battery Cables Optional Equipment: Gas/Gaso Carburation Weather Protective Housing Mounted Exhaust Mounted Fuel Tank Low Oil Piessure Shutdown Hot Air Temperature Shutdown Installed Oil Base Heater Batteries and Electrolyte {L . '*•*=***.*= .^m M. dr-f jjwigi