Loading...
HomeMy WebLinkAboutRes 8106I RESOLUTION NO. S\/£ OF THE TRUCKEE DONNER PUBLIC UTILITY DISTRICT APPROVING SPECIFICATIONS AND CALLING FOR BIDS ON ELECTRICAL DISTRIBUTION EQUIPMENT WHEREAS, the Manager of the Truckee Donner Public Utility District has determined the need to purchase various items of equipment for the District's electrical distribution system during the remainder of the cal- endar year of 1981; and hi.br t WHEREAS, s] K" attached itions for said equipment items are given in Ex- I NOW, THEREFORE, BE IT RESOLVED that the Board of Directors of the Truckee Donner Public Utility District does hereby approve the specifica- tions described Ln Exhibit "A" attached hereto and made a part hereof; BE IT FURTHER RESOLVED that the President of the Board of Directors of the Truckee Donner Public Utility District is hereby directed to issue a call for bids based on the specifications as described in Exhibit "A" for the annual supply of distribution equipment, and that the date and time established for the bid opening is ffl/j£e4 L , 1981, at 4:00 P.M. PASSED AND ADOPTED by the Board of Directors of the Truckee Donner Public Utility District at a special meeting thereof duly called and held in the District on the -VV day of /St?.* _ £j _ , 1981, by the following roll call vote: AYES: NOES: ABSENT: , Aj £&£■& TRUCKEE IXJNNEH PUBLIC UTILITY DISTRICT «-<,*,. Roberta C. Huber, President ATTEST I .^.m , %? Susan M. Craig, Deputy District Clerk 2/3/81 TRUCKEE-DONNER PUBLIC UTILITY DISTRICT POST OFFICE BOX 309 TRUCKEE, CALIFORNIA 95734 TELEPHONE 587-3896 / I To Prospective Bidders of Electrical Distribution Equipment: I The intention of the Truckee-Donner Public Utility District in issuing the attached Call for Bids is to select distribution equipment suppliers from whom the District will purchase such equipment for the calendar year of 1981. The successful bidders will be issued blanket purchase orders for an approximate number of items. Authorization to ship against this blanket purchase order will be issued from time to time. Equipment other than that indicated in the call for bids also may be ordered periodically. The District does not guarantee that they will purchase the number of items indicated; it will, however, purchase all items required from the suppliers selected unless a supplier cannot meet the District's needs. By calling for bids on our estimated annual requirement, the District's intention is to give the selected suppliers advance information for production planning. Sincerely, Douglas E. Holt General Manager DEH/nj / SCHEDULE 1981 ELECTRIC METER BID (SINGLE PHASE) I Item Quantity 576 Specifications Single Phase Electric Watt Hour Meter 3 wire, 240 volt, 4 terminal. Class 200, 30 test Amps, with Polycarbonate or Lexan cover. Register: Cyclometer type, 5x1 dials Manufacturer: Duncan Meter Co. Type: MS 200 Catalog Number: 9101-1158 except with Polycarbonate cover Manufacturer: Sangamo Meter Co. Type: J 4 S Catalog Number: 76068 I Manufacturer: Type: Catalog Number: GENERAL SPECIFICATIONS FOR SINGLE PHASE METERS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed in REA list of acceptable materials. f * SCHEDULE 1981 ELECTRIC METER BID (SINGLE PHASE) I Item Quantity 2 4 Specifications Single Phase Electric Watt Hour Meter 3 wire, 240 volt, 6 terminal, Class 10 or 20, 2.5 test Amps, with Polycarbonate or Lexan cover. Register: Cyclometer type, 4 x transformer rating Manufacturer: Duncan Meter Co. Type: MS-4S Catalog Number: 9101-1162 except with Polycarbonate cover I Manufacturer: Sangamo Meter Co. Type: J4S Catalog Number: 76389 Manufacturer: Type: Catalog Number: GENERAL SPECIFICATIONS FOR SINGLE PHASE METERS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed in REA list of acceptable materials. # SCHEDULE 1981 ELECTRIC METER BID (SINGLE PHASE) I Item Quantity 3 4 Specifications Single Phase Electric Watt Hour Meter 3 wire, 240 volt, 4 terminal, Class 320 (extended range), 30 test Amps, with Polycarbonate or Lexan cover. Register: Cyclometer type, 5 x 1 dials Manufacturer: Duncan Meter Co. Type: MS-E 320 Catalog Number: 9101-1164 except with Polycarbonate cover Manufacturer: Sanqamo Meter Co. Type: J4ES Catalog Number: 76315 I Manufacturer: Type: Catalog Number: Note: These meters will be used in conjunction with Western Utilities Electric Service Standardization Com- mittee Standards Section 200, Page 225.2. If manufacturer of this meter requires a special socket, please so desig- nate and specify type socket. GENERAL SPECIFICATIONS FOR SINGLE PHASE METERS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed in REA list of acceptable materials. SCHEDULE 1981 ELECTRIC METER BID (NETWORK S POLYPHASE) I I Item Quantity Specifications 48 Network Polyphase Watt Hour Meter 3 wire, 120 volt (208 volt Wye service), 5 terminal, Class 200, 2 stator, 30 test Amps, with Polycarbonate or Lexan cover. Register: Cyclometer type, 5 x 1 dials Manufacturer: Duncan Meter Co. Type: MT-12 S Catalog Number: 9402-2600 except with Polycarbonate cover and Cyclometer register I Manufacturer: Sangamo Meter Co. Type: S12S Catalog Number: 65004 except with Lexan cover Manufacturer: Type: Catalog Number: GENERAL SPECIFICATIONS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed In REA list of acceptable materials. SCHEDULE 1931 ELECTRIC METER BID (NETWORK 8 POLYPHASE) / Item Quantity I Specifications Polyphase Watt Hour Meter 3 wire, 480 volt, Class 100, 2 stator, 5 terminal, 15 test Amps, no demand, with Polycarbonate or Lexan cover. Register: Cyclometer type, 5 x 1 dials Manufacturer: Duncan Meter Co. Type: MT-12S Catalog Number: 9402-2598 except with Polycarbonate cover and Cyclometer register Manufacturer: Sangamo Meter Co. Type: S2S Catalog Number: 63479 except with Lexan cover I Manufacturer: Type: Catalog Number: GENERAL SPECIFICATIONS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed in REA list of acceptable materials. & SCHEDULE 1981 ELECTRIC METER BID (NETWORK & POLYPHASE) Item Quantity I Specifications Polyphase Watt Hour Meter 3 wire, 480 volt, Class 200, 2 stator, 5 terminal, 30 test Amps, no demand, with Polycarbonate or Lexan cover. Register: Cyclometer type, 5 x 1 dials Manufacturer: Duncan Meter Co. Type: MT-12S Catalog Number: 9402-2604 except with Polycarbonate cover and Cyclometer register Manufacturer: Sanqamo Meter Co. Type: S2S Catalog Number: 63606 except with Lexan cover I Manufacturer: Type: Catalog Number: GENERAL SPECIFICATIONS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed in REA list of acceptable materials. i SCHEDULE 1981 ELECTRIC METER BID (NETWORK & POLYPHASE) I Item Quantity 4 20 Specifications Polyphase Watt Hour Meter 4 wire, 120/208 Wye, Class 200, 3 stator, 7 terminal, 30 test Amps, no demand, with Polycarbonate or Lexan cover. Register: Cyclometer type, 5 x 1 dials Manufacturer: Duncan Meter Co. Type: MT-16S Catalog Number: 9402-2634 except with Polycarbonate cover and Cyclometer register Manufacturer: Sangamo Meter Co. Type: S4S Catalog Number: 69320 except with Lexan cover I Manufacturer: Type: Catalog Number: GENERAL SPECIFICATIONS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed in REA list of acceptable materials. i t SCHEDULE 1981 ELECTRIC METER BID (NETWORK & POLYPHASE) I Item Quantity 5 4 Specifications Polyphase Watt Hour Meter 4 wire, 277/480 Wye, Class 200, 3 stator, 7 terminal, 30 test Amps, no demand, with Polycarbonate or Lexan cover. Register: Cyclometer type, 5 x 1 dials Manufacturer: Duncan Meter Co. Type: MT-16 S Catalog Number: 9402-2636 except with Polycarbonate cover and register dial I Manufacturer: Sanqamo Meter Co. Type: S4S Catalog Number: 69589 except with Lexan cover Manufacturer: Type: Catalog Number: GENERAL SPECIFICATIONS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed in REA list of acceptable materials. / SCHEDULE 1981 ELECTRIC METER BID (NETWORK & POLYPHASE) Item Quantity Specifications I Polyphase Watt Hour Meter 4 wire, 120 volt, Wye, Class 20, 3 stator, 13 terminal, 2.5 test Amps, no demand, with Polycarbonate or Lexan cover. Register: Clock type, 4 x transformer rating dials Manufacturer: Duncan Meter Co. Type: MT-9 X Catalog Number: 9402-2586 except with Polycarbonate cover I Manufacturer: Sangamo Meter Co. Type: S4S Catalog Number: 69180 except with Lexan cover Manufacturer: Type: Catalog Number: GENERAL SPECIFICATIONS Must meet REA specifications per Bulletin 161-12 for Watt Hour Meters and be listed in REA list of acceptable materials. I SCHEDULE 1981 CUT-OUT ARRESTOR COMBINATION DEVICES (POLE MOUNT) BID I Quantity 88 Description 10 Kv SO Amp SPECIFICATIONS FOR CUT-OUT ARRESTORS General Voltage Rating REA Must be equivalent to McGraw Edison type E-6-STF or Kearney #123623 10 Kv Must be listed in REA list of acceptable materials I SCHEDULE 1901 2/0 TRIPLEX SERVICE WIRE BID I Quantity 16,500' Description Runcina Packaging 1500' Non-returnable reels Voltage Rating REA SPECIFICATIONS FOR TRIPLEX WIRE 600V Must meet REA specification D-2 for Triplex Service Cable and be listed in REA list of acceptable materials. SCHEDULE 1981 HZ TRIPLEX SERVICE WIRE BID I Quantity 33,000' Description Conch Packaging 1800' Non-returnable reels I Voltage Rating REA SPECIFICATIONS FOR TRIPLEX WIRE 600V Must meet REA specification D-2 for Triplex Service Cable and be listed in REA list of acceptable materials. SCHEDULE 1931 1 0 POLE MOUNTED CONVENTIONAL DISTRIBUTION TRANSFORMER BID I ntity Description 30 25 Kva 120/240 25 37 1/2 Kva 120/240 6 50 Kva 120/240 G 25 Kva 240/480 3 37 1/2 Kva 240/480 I SPECIFICATIONS FOR CONVENTIONAL POLE MOUNTED DISTRIBUTION TRANSFORMERS Primary Voltage Secondary Voltage Bushing Taps Tap Changer REA 7200/12470 Y (As per description) 2-primary 2-secondary 5% above and below normal in 2 1/2% steps Must be external Transformers furnished must meet REA specification #0-10 and be listed on the REA list of acceptable materials. ,l> SCHEDULE 1901 10 PAD MOUNT TRANSFORMER BID Quantity I Description 75 Kva 50 Kva 25 Kva I SPECIFICATIONS FOR SINGLE PHASE PAD MOUNTED TRANSFORMERS Primary Voltage 12470Y/7ZOO Secondary Voltage 240/120 Construction Fuses Secondary Taps REA Oil immersed, self-cooled, 50 Hz, 65° temp. rise, 95Kv BIL loop feed, dead front, high voltage bushings, auto pressure relief Load sensing bayonet with provisions for distribution arrestors Stud connections, 5/8" bronze stud through 112 l/2Kva - 1" bronze stud over 112 l/2Kva 5% above and below normal in 2 1/2% steps Must meet REA specification #U-5 and be listed in REA list of acceptable materials