Loading...
HomeMy WebLinkAbout5 Broadband Services Agenda Item # Memorandum To: Board of Directors From: Peter Holzmeister Date: March 15, 2002 Subject: Broadband services It was suggested at the last Board meeting that the question of the District offering broadband services be placed on an election ballot so the voters of the District could decide the issue. The matter is on this agenda so the Directors can discuss the proposal and make a decision. Thoughts for your consideration: 1) The beauty of the election is that you would not need to make the decision; it wold be entirely in the hands of the voters. 2) The down side is that the Board has a great deal of information and the voters do not. This is why representative government works. 3) People who do not want to buy broadband services from the District do not need to. They can continue to buy services from other providers, thus voting every day and changing their votes from time to time as circumstances suggest. 4) There are other ways to gage citizen interest, such as a public hearing or a mailed survey. A tl Figure 1 — Tensile Strength E Ductile Iran 80,000 PVC o. 70,000 71,400 Ultimate c 600000 60,000 Ultimate cm 50,000 c 51.900 Yield - m 42.000 Yield y 40,000 m 30,000 20,000 109000 Ultimate Ultimate Yield 79000 7,700 5.800 Minimum Values Measured Values per Applicable from Standards (AWWA Production Pipe - C151 and AWWA C900) ' _ _ .1 w _ � .tin�f r+,.. � Z � .,,f.� n g ✓k?"' -' ri? ..- t;n 1r Y. COST DUCTILE IRON PVC 8" $11 .80/ft $4.95/ft 12" $18.25/ft $10.62/ft POLICY GUIDELINES FOR PIPE MATERIAL APPLICATION SPECIAL CONDITION: As identified by Water System Engineer 1) AGGRESSIVE (CORROSIVE) SOIL CONDITIONS: If soil conditions are identified that are corrosive in nature, then PVC pipe spldi. be specified for installation in this area. 2) IRRIGATED AREAS: (Golf Courses) ( If a pipeline is to be installed in an irrigated area, then PVC pipe shad be specified for installation in this area. 3) CONTAMINATED SOILS: If a pipeline is to be installed in an area that has a likely potential for contamination from petroleum products, then Ductile Iron pipe should be specified for installation in this area. , O" 4) HIGH PRESSURE: If a pipeline is to be installed in an area that has a potential for operating pressures to exceed 150 psi, then Ductile Iron pipe should be specified for installation in this area. 5) SHALLOW BURIAL: If a pipeline is to be installed in an area were due to alignment conflicts the depth of cover is less than 4 feet, then Ductile Iron pipe should be specified for installation in this area. STANDARD CONSTRUCTION CONDITIONS: For standard construction condition both PVC Class 150 and Ductile Iron Class 350 pipe will be acceptable for pipeline material. Memorandum To: Board of Directors From: Ed Taylor, Water Utility Manager Date: 3/20/2002 BACKGROUND: Staff has reviewed with the Board on three occasions the change of material standards to include plastic pipe for pipeline material. At the last meeting a presentation by representative from the Ductile Iron and the Plastic pipe industries was conducted. The District has chosen to utilize Ductile Iron Pipe for all pipeline replacements in the District. Staff has review pipeline materials and believes that plastic pipe(PVC)would be an appropriate pipeline material for pipelines in the District. RECOMMENDATION: Staff recommends that the Board adopt a policy approving the use of Plastic pipe (PVC) for water mains in the District per the attached guidelines. List of what other agencies in the area are using. Agency PVC DIP Carson City Water Utilities Yes Yes Incline Village General Improvement District Yes Yes North Tahoe Public Utility District Yes Yes South Tahoe Public Utility District Yes Yes Tahoe City Public Utility District Yes Truckee Meadows Water Authority(Reno & Sparks) 10" and Smaller 12" and Larger Washoe County Yes Yes 0 Page 1