HomeMy WebLinkAboutRES 1987-52 - Board RESOLUTION NO.8752
OF THE
TRUCKEE DONNER PUBLIC UTILITY DISTRICT
APPROVING SPECIFICATIONS AND CALLING FOR
BIDS ON A HIGH PRESSURE WASHER
WHEREAS , the Board of Directors of the Truckee Donner Public Utility
District has determined the need to purchase a high pressure washer for
assistance in cleaning the District's water tanks;
NOW, THEREFORE, BE IT RESOLVED that the Board of Directors of the Truckee
Donner Public Utility District does hereby authorize the President to issue
a call for bids based on the specifications and contract documents attached
hereto, and that the date and time established for the bid opening is
Friday, December 11 , 1987 at 11:00 A.M.
PASSED AND ADOPTED by the Board of Directors of the Truckee Donner Public
Utility District at a meeting thereof duly called and held in the District
on the 23rd day of November, 1987, by the following roll call vote:
AYES: Aguera, Maass, Sutton and Corbett.
NOES: None.
ABSENT: Cooley.
TRUCKEE DONNER PUBLIC UTILITY DISTRICT
By
J61,
L. Corbett , President
ATTEST:
Susan Macdonald , Deputy District Clerk
sm d2a/60
SPECIFICATIONS
FOR
HIGH PRESSURE WASHER
Water pump volume. . .. . .. . . .. . ..... .. . ..4 GPM (15.1 lmp); 240 GPH (908.4
1ph)
Water pump pressure. . .. .. . .. .. ... .. . . . .2 ,000 PSI (140.6 kg/cm2)
Water pump. ..... . . .... . . . .... . . ... . .. . .Hawk triplex, positive-displacement
pump; ceramic plungers; bronze
manifold; anodized-aluminum,
oil-bath crankcase
Pump drive:
Electric motors. .. .. . . .. . .... .. . . .5 HP; 230 V, 60 C, 1 or 3 P; thermal
overload protection; drip proof
Gasoline engines. . . . . . . . .... ... . ..11 HP; electric start; battery and
generator; Briggs & Stratton engine
Oil-fired burner:
Type. .. ...... ... .. .. ... .. .. .. . .. . .Pressure-atomizing; forced-air;
automatic electric ignition; UL
approved
Motor. . ... ...... . . .... . .... .. ... . .1/8 HP electric; 3,450 RPM; 115 V,
60 C, 1 P; thermal overload
protection
Burner nozzle size* * so* 9 *see **see *295 GPH
Input. ....... ... . ... ... . ..... .. .. .385,000 BTU @ hr.
Fuel type... ...... .. ... ..... ... ... 1 or #2 diesel, kerosene , #1 home
heating oil
Fuel tank. ........ .... ...... . ... . .11-1/2 gallons capacity; removeable;
non-contaminating; high-density
polyethylene; verticle mount burner
Heating coil.. ... .. a*** ** * so *7/811 OD; continuous length seamless
steel tubing; Schedule 80; 39000 PSI
hydrostatic-pressure tested; 14,600
PSI burst-pressure rated; vertically
fired.
Stack size (diameter). . . . . . . . . .. .. . . . . .8" oil fired
Controls:
Temperature* .. .. - -- - ,,. . ..Solid state; adjustable to control
water temperature to 210 degrees F
Safety relief valve. .. . . .. . . .. . . ..Preset to release pressure for
component protection
Pressure switch. . . . . ... . . .. . ... . ..High-pressure type provides
automatic , burner-shutoff protection
Unloader... ... . .. .. ... . . .... . . .. . .Provides pressure relief for pump
when trigger gun is closed
Pump motor switch. .9 e e o * 9 e -Manual starter with automatic
overload protection (electric models
only)
Burner switch. .. . .. .. .. .... ... . .. .Heavy-duty toggle switch
Soap valve. .. ...... . .......... . . ..Chemical orifice system for precise
measuring
Float valve. .. .. .. . .. . . .... .... . . .Automatic; non-contaminating
Float tank..... ... .. .... . ... .... .. .. . ..Non-corrosive; non-contaminating;
high-density polyethylene
Gun. . .. 9 9*99** 9* * e999 * *Trigger shutoff with cool grip
Wand. .. .. . . .... ...... ... . . .. . ..... .. . . .Heavy-duty with insulated grip;
extra extensions optional
Nozzles.. . ..... .. . .. .. . .... . ..... .. .. ..Three stainless steel; one 0
degrees, one 15 degrees, one 40
degrees
Hose. .. so * eeo . .3/8" ID; 1501 ; single-wire braid;
29250 PSI working-pressure rated;
oil and chemical resistant
Portability. .. ... .. .. 9 *9 && e99 *99* *o o * 9*4 heavy-duty pneumatic wheels with
swivle base, tongue and handle
Optional accessories* ** . . .. . someeoet ** *Quick couplers for hose and wand;
hose reel with minimum of 250' of
3/8 hose capacity mounted to unit
Materials. . . .. . .... . .. .. . . . .. .. . . .. . . ..Heavy-gauge steel; angle-iron frame
Finish. . . . .. .. .. .... . . . . .. . . . ... .. .. . ..High-gloss , baked enamel
Dimensions. .. . . . ... ... ... .. .. ... . .. . . . .L-45" (114.3 cm); W-18" (45.72 cm);
H-48" (121.92 cm)
Generator. ... .... . .. . . . . . . .. .. .. .. .. . . .2 kw, capable of running off the 11
HP gas engine to provide power for
the burner
The preceeding specifications are meant to describe the minimum standards
acceptable to the District. We will accept any equipment that is substan-
tially equal to or better than these specifications, in the opinion of the
District.
FORM OF PROPOSAL
HIGH PRESSURE WASHER
I certify that I have read the Truckee Donner Public Utility District's
instructions to bidders and specifications for a high pressure washer, and
hereby submit the following bid.
Purchase price (FOB Truckee)
Applicable tax
Total
Name of firm
Address
Proposal submitted by
Title
If the bid is awarded to me I will deliver the high pressure
washer to Truckee within calendar days after receiving
formal notice.
The above price shall remain in effect for 60 calendar days from
the date of the bid opening.
sm/d10.35